• Simple handling and low space requirements
  • Voltage ratings 230V, 400V, 500V
  • Current rating 8A … 280A
  • Integrated semiconductor fuses
  • Standard system interface for connection to an optional bus module (e.g. Profibus-DP or Modbus RTU)
  • LED status indicators
  • Operational modes 1:1, as well as 1:2, 1:3, 1:5 (e.g. for commissioning)
  • 24V logic signal control (>3V) or over standard system interface
  • Secure isolation between control and power sections
  • 3-phases structure by connecting two Thyro-S units
  • UL approval
  • Meet ISO 9001 quality standards
  • CE conformant
 
THYRO-S

 

 

 

 

 

 

 

 

  • Simple handling and low space requirement
  • Voltage rating 230V, 400V, 500V
  • Current ratings 8A … 280A, in single and dual phase configurations.
  • Integrated semiconductor fuses
  • LED status indicators
 
THYRO-A

 

 

  • Ease of handling for rapid and reliable start-up.
  • Ease of connection to automation equipment via bus communications.
  • Transformer load, ohmic load and heating elements with large Rhot / Rcold.
  • Integrated soft-starting for operation with downstream transformer.
  • Dynamic mains load optimization (patented process, ease of handling).
  • Wide band power supply for control voltage.
  • 6-LED status indicators.
  • Centralized fault indication.
  • Error memory with event time.
  • Integrated load circuit monitoring.
  • Graphics-capable control options.
  • High efficiency, zero-wear operation between power and control section that meets VDE 0160.
  • Connection to SELV/PELF circuit.
  • Quality standard to DIN EN ISO 9001.
  • UL certification.
  • Voltage: 230 – 690V
  • Current: 37A – 2,900A
  • CE – compliant.

 

 
 


THYRO-P

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 


Frequently Asked Questions

 

What is a power unit required for?

By means of a power controller, it is possible to supply well regulated or controlled electric energy (e.g. monitored, non-wearing, with high efficiency) to a consumer.

 

Which kind of load can be connected to an AEG SVS power controller?

  • Resistive load
  • Resistive load with large warm / cold resistance ratio
  • Transformer load (transformer with resistive load)
  • Capacitive load (Thyro-C only)

 

Which types of power controller are available within the Thyro family?

  • Single-phase controlled, for single-phase loads
  • Two-phase controlled, for two-phase loads (so-called saver circuit)
  • Three-phase controlled, for three-phase loads
  • Type current 8 A to 2900 A
  • Type voltage 230 V to 690 V
  • Type power 1,8 KW to 2.8 MW

 

What is the difference between a thyristor switch and a thyristor power controller?

Thyristor switch
Depending on the control signal, the load is fully switched to the line voltage or idle. In connection with a temperature controller, the thyristor switch can be used, e.g., for two-position actions.

 

Thyristor power controller

Proportionally to the control signal, the load is variably supplied with energy. Depending on control mode and power unit, it is possible to implement U-control, U²-control, I-control, I²-control or P-control.

 

Which control modes are available?

  • U-control
  • U²-control
  • I-control
  • I²-control
  • P-control

 

Which operating modes are available?

  • VAR = Phase angle control (according to the set point, each half-wave of the line voltage is more or less connected through to the load).
  • TAKT = Full-oscillation cycle mode operation (within a TAKT period, the load is switched on / off once).
  • QTM = Quick Takt Mode is a fast variant of the TAKT mode and particularly suitable for infrared radiators.
  • SSSD = Soft-Start-Soft-Down (like TAKT, however, with Soft-Start-Soft-Down ramp in the phase angle control).
  • MOSI = Sub-mode of TAKT or VAR for peak current limitation during the heating-up phase of temperature-dependent load resistors.

 


Which types of monitoring are possible?

  • Device monitoring
  • Load monitoring (also partial load)
  • Line voltage monitoring

 

 

 

 

Which synchronization procedures are available?

Synchronization procedures can be used for applications with several power controllers. They serve to minimize the mains loading and thus to minimize investment and operating costs. They simultaneously minimize mains feedback.

 

How to select the most suitable power controller?

  • The required load power and the available voltage determine the type power of the actuator.
  • The kind of load (resistive load, transformer load) determines, together with the requirements on the dynamic accuracy, the type series and the number of phases to be controlled.
  • In case of loads / applications which can be operated in the TAKT mode, a thyristor power unit with saver circuit (2 controlled phases: => smaller, lighter, less power loss, more cost-saving) can be used.

 

From the customer:

 

Secure, fast, no contacts and communication capable
Ready-to-plug digital thyristor switches with integrated semi-conductor fuses to ensure the wear-free switching of currents, voltages, and power. Our new Thyro-S switches can of course also be operated via the usual bus interfaces within an automated system.Stand-alone operation or in combination with process controls, PLC, or automation systems via various bus interfaces.

 

"During refinement, too, we trust in the reliable temperature control by means of AEG Thyro-S actuators."
Christoph Gruß, Head of the Electrical Engineering Department
Ritzenhoff Cristal

 

Universal, configurable and communication capable Ready-to-plug digital thyristor controllers with operating modes: full-wave cycle principle (Thyrotakt), phase-control principle (Thyrovar) and Quick-Takt-Mode QTM (for 1-phase devices). Integrated semiconductor fuse, bus interface, and the optional power regulation, all just as much part of the product as the large number of monitoring functions and the facility for optimizing mains load with synchro-cycle SYT or direct in QTM operation mode.
Stand-alone operation or in combination with process controls, PLC, or automation systems via various bus interfaces. The tried-and-trusted Thyro-3AX is still available for three-phase applications.

 

"We were looking for a solution which allowed fast and non-wearing switching. We have found it in the form of the thyristor power units from AEG."
Dr. Hans Pelster
DMV Stainless

 

Digital controller with communications capability User-friendly thyristor power controller for the exact control and regulation of currents, voltages, and power.

Its wide voltage and current range and the systematic application of our many years of experience in the field of power controllers make the Thyro-P our high-end product. With a large number of operating modes and regulating and recording functions, this power controller shows the way into the future and can be used in wide areas of the thermo-processing technology.

Stand-alone operation or in combination with process controls, PLC, or automation systems via various bus interfaces.

 

"With our small, but excellent float installation, we have achieved a quality in the borosilicate flat glass production which is unique world-wide up to now."
Dr. Gerhard Lautenschläger, Manager of the Special Float Glass Department
Schott Jenaer Glas GmbH

 

 

 

 

If you have any inquires, kindly contact us via fax or email. We promise to attend to your request as soon as possible.

 

 

 

NEX Scientific Instrument

NEX Control Technology(USA)

 

Email  : sales@nex.myqtgroup.com